The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement
and control. Level detection is accomplished by using a high-resolution thermal differential
technique. The sensor wetted parts are of durable 316L series stainless steel, all-welded
construction and contain no moving parts. The switch is easy to install and adjustable
providing reliable, low-maintenance performance in the most demanding applications.
T21 Thermal
Differential Switch
General Instructions
Table of Contents
Installation
Mechanical ................................ 2-3
Electrical .....................................4
Set up and Operation ...........................5
Calibration for Level Switches ............. 6-7
Calibration for Flow Switches .............. 8-9
Dimensions .................................... 10
Cleaning ........................................ 11
Troubleshooting ........................... 11-12
Design and
specifications are
subject to change
without notice.
For latest revision,
go to sorinc.com
Registered Quality System to ISO 9001
NOTE: If you suspect that a product is defective, contact the factory or the SOR
®
Representative in your area for a return authorization number (RMA). This product should
only be installed by trained and competent personnel.
able
,
low maintenance
performance
in
the
most
demanding
ap
t
t
h
t
d
t
i
d
f
t
t
th
f
t
t
h
S
OR
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Differential Switch

Form 1024 (08.13) ©SOR Inc. 1/12The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detectio

Pagina 2 - Mechanical Installation

10/12Form 1024 (08.13) ©SOR Inc. DimensionsPROCESSCONNECTIONAB1/2 NPTM172.56.7914.30.563/4 NPTM156.06.1419.10.751 NPTM175.06.8919.10.751-1/2 NPTM173.7

Pagina 3 - *Sensor Length =

Form 1024 (08.13) ©SOR Inc. 11/12CleaningThe probe may be cleaned by soaking, spraying solvents or detergent and water onto the sensor tubes, or by ul

Pagina 4 - Electrical Installation

12/12Form 1024 (08.13) ©SOR Inc. 14685 West 105th Street, Lenexa, KS 66215  913-888-2630  800-676-6794 USA  Fax 913-888-0767Registered Qualit

Pagina 5 - Setup and Operation

2/12Form 1024 (08.13) ©SOR Inc. The T21 has a 3/4-inch MNPT mount (standard), designed for easy installation through a threaded port. Conduit is rec

Pagina 6

Form 1024 (08.13) ©SOR Inc. 3/12Pipe Wall Thickness*SensorLengthPipe Nozzle/CouplingLength Unit can be mounted above or below pipe. Mounting on top of

Pagina 7

4/12Form 1024 (08.13) ©SOR Inc.  Remove the instrument enclosure lid by unscrewing in a counterclockwise direction. Loosen the two, board-retaining

Pagina 8 - Calibration for Flow Switches

Form 1024 (08.13) ©SOR Inc. 5/12 Remove the instrument head cover. Turn counterclockwise to expose the electronics. Turn on power at its source. Ob

Pagina 9

6/12Form 1024 (08.13) ©SOR Inc. Calibration for Level SwitchesFor optimum operation, calibration must be accomplished at actual process temperature an

Pagina 10 - Dimensions

Form 1024 (08.13) ©SOR Inc. 7/121000Trip AdjustWetDryL1 Red “ON” for Dry/No FlowFuse F1J2L2 Green “ON” for Wet/ Ful

Pagina 11 - Troubleshooting

8/12Form 1024 (08.13) ©SOR Inc. NOTE: This adjustment may be done for tripping points between 10% and 90% of the span from no  ow to max  ow.Calibra

Pagina 12 - Printed in USA sorinc.com

Form 1024 (08.13) ©SOR Inc. 9/121000Trip AdjustSpanZeroFuse F1J2PC Board Retention Screw (2)J1High Flow/LevelLow FlowJ1NOTE: For use as Flow

Comentarios a estos manuales

Sin comentarios