Form 425 (08.12) ©2012 SOR Inc.
1/16
Level Switches are available for a range of industrial applications. ATEX-certified options
for potentially explosive atmospheres are available for both flameproof and intrinsically
safe protection.
Level Switches
General Instructions
Registered Quality System to ISO 9001:2008
Design and
specifications are
subject to change
without notice.
For latest revision, go to
www.sorinc.com
Table of Contents
Float-Operated Switches, Vertical ...........2
Displacer-Operated Switches, Vertical ......3
Float-Operated Switches, Horizontal ........4
Switch and Switch Chamber Installation ....5
External Chamber Installation .............5
Single Switch Chamber Installation ......6
Multiple Switch Chamber Installation ...7
Float Attachment ................................8
Electrical Wiring Instructions .................9
SIL Instructions .................................9
Wiring Mechanism ........................... 10
Set Point ....................................... 11
Differential ..................................... 11
Pneumatic Piping ............................. 11
Switch Ratings ................................ 12
Preventive Maintenance ..................... 12
Troubleshooting ............................... 13
ATEX Information ............................. 14
Declaration of Conformity ................... 15
Service Policy ................................. 16
Limited Warranty ............................. 16
200 Series
Sealed
Chamber
F
D
F
S
700 Series
Top-Mounted
Displacer
100 Series
Flanged
Chamber
NOTE: If you suspect
that a product is
defective, contact
the factory or the
SOR
®
Representative
in your area for a
return authorization
number (RMA).
This product
should only be
installed by trained
and competent
personnel.
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Level Switches

Form 425 (08.12) ©2012 SOR Inc. 1/16Level Switches are available for a range of industrial applications. ATEX-certified options for potentially explo

Pagina 2

10/16Form 425 (08.12) ©2012 SOR Inc. Wiring Mechanism123CNO2NCCC2NO NO2NONC2NCNC2C2NO1C1NC1NC1NO1C1Float Position SPDT Mechanism DPDT MechanismSOR Co

Pagina 3

Form 425 (08.12) ©2012 SOR Inc. 11/16Rising level set point is the level at which actuation occurs. Falling level set point is the level at which dea

Pagina 4

12/16Form 425 (08.12) ©2012 SOR Inc. Switch TypeResistive Amperage Inductive Amperage110-130 VAC210-250 VAC20-30 VDC110-130 VDC210-250 VDC110-130 VAC2

Pagina 5 - External Chamber Installation

Form 425 (08.12) ©2012 SOR Inc. 13/16 Is the control being operated within the nameplate limitations? Is power connected to the control? Is the po

Pagina 6 - Drawing 0390737

14/16Form 425 (08.12) ©2012 SOR Inc. Sample NameplatesThe following pressure ratings are available for SOR Level Switches. Flange Connection (150# to

Pagina 7

Form 425 (08.12) ©2012 SOR Inc. 15/16Declaration of ConformityProductManufacturerDate of IssueWe declare that the above products conform to the follo

Pagina 8 - Float Attachment

16/16Form 425 (08.12) ©2012 SOR Inc. 14685 West 105th Street, Lenexa, KS 66215  913-888-2630  800-676-6794 USA  Fax 913-888-0767Registered Qu

Pagina 9

2/16Form 425 (08.12) ©2012 SOR Inc. Float-Operated Level Switches - VerticalOperation  The float rides on the process liquid surface, precisely trac

Pagina 10 - Wiring Mechanism

Form 425 (08.12) ©2012 SOR Inc. 3/16Operation  Displacer controls offer alternate features to the float-operated control. The sensor is a weight (

Pagina 11 - Pneumatic Piping

4/16Form 425 (08.12) ©2012 SOR Inc. Float-Operated Level Switches - HorizontalSwitching Element ActuatedMagnetic Field EngagedAttraction Sleeve UpCoun

Pagina 12 - Preventive Maintenance

Form 425 (08.12) ©2012 SOR Inc. 5/16Switch and Switch Chamber Installation Verify that obstructions are not present in the application which would

Pagina 13 - Troubleshooting

6/16Form 425 (08.12) ©2012 SOR Inc.  Locate switch chamber process connection 12” to 24” (300mm to 600mm) away from the process pipe or tank.

Pagina 14 - Drawing 3120280

Form 425 (08.12) ©2012 SOR Inc. 7/16Multiple Switch Chamber InstallationDeviating from any of these recommendations may adversely affect operation of

Pagina 15 - of Conformity

8/16Form 425 (08.12) ©2012 SOR Inc. Float AttachmentFlanged Process Connection Place the Stem with Attraction Sleeve inside the flange of the Switch

Pagina 16 - Service Policy

Form 425 (08.12) ©2012 SOR Inc. 9/16NOTE: For ATEX or IEC Certi ed T6 and S3 Enclosures: Electrical conduit connection threads may be of non-ISO thr

Comentarios a estos manuales